Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 199(15-16): 2015-2019, 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37819286

RESUMO

In a nuclear or radiological accident scenario, when potentially members of the public can undergo internal contamination by anthropogenic radionuclides released in the atmosphere, effective methods that can be used directly in the field to perform a fast scan for internal contamination on a large number of individuals can play a major role to undertake appropriate countermeasures. Specific attention should be paid to the individual monitoring of children since they constitute the sensitive population group with the highest risk of developing cancer. At the ENEA Casaccia Research Center in Rome (Italy), monitoring procedures based on a portable HPGe detector and ratemeters were tested in the field. A total of 170 acquisitions of uncontaminated volunteers for the blank measurements were collected, 105 acquisitions on adult and 65 acquisitions on 10-y/o children. The detection limit calculation, in terms of activity taken up (Bq), was carried out according to the Standard ISO's 11929 and 28218, whereas the corresponding 'minimum effective dose' (mSv) was calculated based on international commission on radiological protection (ICRP) Publications 134, 137 and 141. Results and evaluations of the measurement campaign are presented and discussed in respect to the aspects reported in the current literature.


Assuntos
Monitoramento de Radiação , Proteção Radiológica , Radioisótopos , Adulto , Criança , Humanos , Itália , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Radioisótopos/análise
2.
J Radiol Prot ; 40(1): 134-150, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31569086

RESUMO

The results obtained in a measurement campaign concerning internal contamination by the gamma-emitting radionuclides of a large number of individuals are presented in this work. The aim is to assess the effectiveness of the spectrometric method in an emergency response following a nuclear power plant accident or a spread of radionuclides in the atmosphere due to an act of terrorism. An HPGe portable spectrometer, deployed in a collective protection apparatus, was used for both whole-body and thyroid measurements. An adult bottle mannequin absorption (BOMAB) and thyroid phantoms were used to evaluate the detector performance. The BOMAB phantom was provided by the Italian Institute of Ionizing Radiation Metrology (INMRI) for the ENEA intercomparison exercise. Thyroid phantoms were provided by the Belgian Nuclear Research Centre for the 'Child and Adult Thyroid Monitoring After Reactor Accident' European intercomparison exercise. The instrument performance was further evaluated by collecting spectral data from healthy volunteers, using acquisition times of 180 s and 100 s, respectively, for the whole-body and thyroid measurements. The detector showed good accuracy in quantifying radionuclide activities in the adult BOMAB and in the thyroids of persons of all ages. The proposed method allows us to detect in vivo activity leading to a committed effective dose E(50) and committed thyroid equivalent doses H T greater than 2 mSv due to all gamma-emitting fission products, if the scan is performed within five days after intake. Assuming, for instance, an acute inhalation of 137Cs and 131I, the obtained detection limit values for adults lead to a E(50) value equal to 0.08 mSv and an H T value of 0.27 mSv. The E(50) and H T values show that the proposed method can be successfully used when the dose assessment must be rapidly performed for a large number of individuals in the eventuality of the scenarios previously mentioned.


Assuntos
Exposição à Radiação/análise , Monitoramento de Radiação/instrumentação , Liberação Nociva de Radioativos , Glândula Tireoide/efeitos da radiação , Contagem Corporal Total/instrumentação , Radioisótopos de Césio/análise , Humanos , Radioisótopos do Iodo/análise , Manequins , Terrorismo
3.
J Radiol Prot ; 38(4): 1454-1468, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30398166

RESUMO

In order to properly respond to an emergency caused by an accident in a nuclear power plant with a spread of radionuclides in the atmosphere, we propose a field procedure to perform a large-scale individual thyroid monitoring of internal contamination due to inhalation of 131I, by means of non-spectrometric equipment, in particular dose rate meters. Specific attention is paid to the individual monitoring of children, because of the very high radiosensitivity of the child's thyroid to the carcinogenic effects of ionising radiation. The device performance was evaluated by measuring mock iodine sources provided in the Child and Adult Thyroid Monitoring After Reactor Accident (CAThyMARA) intercomparison and, just for a scintillator dose rate meter, by means of 60 s acquisitions of healthy volunteers' thyroids. All the devices showed a remarkable accuracy in quantification of equivalent 131I activity in the thyroids of persons of all ages. The selected scintillator dose rate meter showed detection limit values resulting in a maximum committed equivalent dose to thyroid HT, assuming an acute 131I inhalation occurred five days before the measurement, equal to 10 mSv (related to five-year-old children). Considering the level of HT values associated with the calculated detection limit activities, the proposed procedure has a significant sensitivity to be used for fast internally thyroid monitoring in nuclear or radiological emergencies, allowing daily monitoring a large amount of individuals.


Assuntos
Radioisótopos do Iodo/análise , Monitoramento de Radiação/instrumentação , Liberação Nociva de Radioativos , Glândula Tireoide/efeitos da radiação , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitoramento de Radiação/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...